Configure chamber loss without a unit mismatch
Configure chamber loss without a unit mismatch
Section titled “Configure chamber loss without a unit mismatch”A chamber radius entered in centimetres instead of metres changes the physical problem. This compact how-to shows unit-aware construction of spherical and rectangular wall-loss strategies. The goal is to verify configuration before interpreting a loss rate or running a trajectory.
Use a known population for the configuration check
Section titled “Use a known population for the configuration check”Run with Particula and its example dependencies installed, including the unit conversion dependency. The native preset supplies a discrete, two-mode population for the spherical rate calculation. Temperature is 298 K and pressure 101325 Pa; this page does not evolve that population.
Python · section 1
import particula as par
# Light-weight particle distribution for rate calculationsparticle = par.particles.create_lognormal_binned_particle_data( distribution_type="discrete")T = 298.0 # KP = 101325.0 # PaConvert geometry and the wall-mixing coefficient explicitly
Section titled “Convert geometry and the wall-mixing coefficient explicitly”The spherical builder converts 3.6 h⁻¹ to 10⁻³ s⁻¹ and 60 cm to 0.6 m. The wall eddy parameter in this model has units s⁻¹; it is not a gas diffusivity in m² s⁻¹. The discrete rate is concentration change per bin in m⁻³ s⁻¹. A tiny first-bin rate can reflect negligible occupancy, so it is not a summary of loss across the whole distribution.
Python · section 2
spherical = ( par.dynamics.SphericalWallLossBuilder() .set_wall_eddy_diffusivity(3.6, "1/hr") .set_chamber_radius(60.0, "cm") .build())
rate = spherical.rate(particle=particle, temperature=T, pressure=P)
print("eddy diffusivity [1/s]", f"{spherical.wall_eddy_diffusivity:.3e}")print("chamber radius [m]", f"{spherical.chamber_radius:.2f}")print("distribution type", spherical.distribution_type)print("rate[0]", f"{rate[0]:.3e} m^-3 s^-1")eddy diffusivity [1/s] 1.000e-03
chamber radius [m] 0.60
distribution type discrete
rate[0] -1.897e-88 m^-3 s^-1
Express the same choices as a configuration dictionary
Section titled “Express the same choices as a configuration dictionary”The factory constructs a rectangular strategy with dimensions 1.8 × 1.5 × 1.2 m and coefficient 1.2 h⁻¹ = 3.333…×10⁻⁴ s⁻¹. It selects particle-resolved semantics, but no resolved population is advanced here. Strategy configuration and the representation of the data must match when the strategy is used.
Python · section 3
factory = par.dynamics.WallLossFactory()
rectangular = factory.get_strategy( "rectangular", { "wall_eddy_diffusivity": 1.2, "wall_eddy_diffusivity_units": "1/hr", "chamber_dimensions": (180.0, 150.0, 120.0), "chamber_dimensions_units": "cm", "distribution_type": "particle_resolved", },)
print("rectangular dims [m]", rectangular.chamber_dimensions)print("distribution type", rectangular.distribution_type)print("diffusivity [1/s]", f"{rectangular.wall_eddy_diffusivity:.3e}")rectangular dims [m] (1.8, 1.5, 1.2)
distribution type particle_resolved
diffusivity [1/s] 3.333e-04
Verify configuration before interpreting chamber decay
Section titled “Verify configuration before interpreting chamber decay”The printed values confirm unit conversion and distribution selection; they are not a spherical-versus-rectangular physics comparison. Constructors reject invalid required geometry and coefficient inputs, and the factory rejects unknown strategy names.
For a chamber-specific study, enter measured geometry and a justified wall-mixing parameter, then use the geometry comparison with matched initial populations. Vary the coefficient over its uncertainty range and compare size-dependent survival, rather than treating a successful builder call as a calibrated deposition model.
Explore this topic: Wall deposition